Remote control commands
R&S
®
RTE
1208User Manual 1326.1032.02 ─ 20
Parameters:
<Polarity> POSitive | NEGative
*RST: POSitive
Usage: Asynchronous command
TRIGger<m>:OUT:PLENgth <PulseLength>
Sets the length of the trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suffix.
Parameters:
<PulseLength> Range: 4E-9 to 0.06
Increment: 20E-9
*RST: 100E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:OUT:DELay <Delay>
Sets the delay of the first pulse edge to the trigger point.
The setting is not available if a mask test or measurement is running and the on-viola-
tion event is set to trigger out pulse.
Suffix:
<m>
.
1..3
Irrelevant, omit the suffix.
Parameters:
<Delay> Range: 800E-9 to 1
Increment: 1E-9
*RST: 800E-9
Default unit: s
Usage: Asynchronous command
18.9.20 Actions on trigger
TRIGger<m>:EVENt:BEEP........................................................................................... 1208
TRIGger<m>:EVENt:PRINt........................................................................................... 1209
TRIGger<m>:EVENt:WFMSave.....................................................................................1209
TRIGger<m>:EVENt:RUNexec......................................................................................1209
TRIGger<m>:EVENt:BEEP <Beep>
Generates a beep sound if the command is set to TRIGger.
Trigger