EasyManua.ls Logo

Rohde & Schwarz RTE - Page 1272

Rohde & Schwarz RTE
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1272User Manual 1326.1032.02 ─ 20
MEASurement<m>:SPECtrum:NDBDown <NDbDown>
Defines the threshold until which the samples to the left and right of the peak value are
analyzed in order to determine the "N dB down bandwidth".
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.
Parameters:
<NDbDown> Range: 0 to 100
Increment: 1
*RST: 20
Default unit: dB
Usage: Asynchronous command
MEASurement<m>:SPECtrum:PEXCursion
<Value>
Defines a relative threshold, the minimum level value by which the waveform must rise
or fall to be considered as a peak. To avoid identifying noise peaks, enter a peak
excursion value that is higher than the noise levels.
Suffix:
<m>
.
1..10
The suffix is irrelevant.
Parameters:
<Value>
Usage: Asynchronous command
Firmware/software: Version 2.70
MEASurement<m>:SPECtrum:ATHReshold <Value>
Defines an absolute threshold as an additional condition for the peak search. Only
peaks that exceed the threshold are detected.
This setting is only available for spectrum waveforms. It is valid for cursor measure-
ments, spectrum measurements and peak search.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.
Parameters:
<Value> numeric value
Default unit: dBm
Usage: Asynchronous command
Automatic measurements

Table of Contents

Other manuals for Rohde & Schwarz RTE

Related product manuals