Remote control commands
R&S
®
RTE
1653User Manual 1326.1032.02 ─ 20
Parameters:
<ErrorCRC> ON | OFF
*RST: ON
TRIGger<m>:ETHernet:ERRor:LENGth <ErrorLength>
Enables the trigger on an incorrect length of the sequence - when additional or missing
bits are detected and the sequence of bits is not as expected.
Suffix:
<m>
.
1..3
Parameters:
<ErrorLength> ON | OFF
*RST: ON
TRIGger<m>:ETHernet:ERRor:PREamble
<ErrorPreamble>
Enables the trigger on a frame with invalid preamble.
Suffix:
<m>
.
1..3
Parameters:
<ErrorPreamble> ON | OFF
*RST: ON
TRIGger<m>:ETHernet:FRAMe:CCONdition <CRCOperator>
Sets the operator to trigger on a specific frame check sequence value.
Suffix:
<m>
.
1..3
Parameters:
<CRCOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater Than,
Greater than or equal. These conditions require a destination
address to be set with TRIGger<m>:ETHernet:FRAMe:CMIN.
INRange | OORange
In range, Out of range. Set the minimum and maximum value of
the range with TRIGger<m>:ETHernet:FRAMe:CMIN and
TRIGger<m>:ETHernet:FRAMe:CMAX.
*RST: EQUal
Protocols