Remote control commands
R&S
®
RTE
1774User Manual 1326.1032.02 ─ 20
Usage: Query only
SEARch:RESult:CMSB<m>:FRAMe<n>:STARt? <SearchName>
Returns the start time of the frame within the search result.
Suffix:
<m>
.
*
<n> *
Query parameters:
<SearchName>
Return values:
<Start> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
SEARch:RESult:CMSB<m>:FRAMe<n>:STATe? <SearchName>
Returns the overall state of the frame within the search result: either OK or the relevant
error condition. R&S RTE-K50 marks each frame with a status that indicates whether
the decode succeeded or not.
Suffix:
<m>
.
*
<n> *
Query parameters:
<SearchName>
Return values:
<State> OK | LENGth | UNKNown | INComplete | CRC | PARity
OK
The frame was decoded normally and conforms to the frame
description.
LENGth
The length error indicates that the frame ended prematurely, or
an array in the frame had too few elements. The amount of bits
that the software expected (based upon the user's frame
description) was not found before the frame was terminated.
This might occur because a new frame synchronized, or a gap
appeared between the bits.
UNKNown
Unknown error