Remote control commands
R&S
®
RTE
1925User Manual 1326.1032.02 ─ 20
Parameters:
<Period> Range: 8E-9 to 1000
Increment: 1
*RST: 1E-6
Default unit: s
WGENerator<m>:FUNCtion:PULSe[:WIDTh] <PulseWidth>
Sets the pulse duration for a pulse waveform.
Suffix:
<m>
.
1..2
Parameters:
<PulseWidth> Range: 16.5E-9 to 1000, actual range depends on the
selected frequency
Increment: 1
*RST: 500E-9
Default unit: s
WGENerator<m>:FUNCtion:RAMP[:SYMMetry] <RampSymmetry>
Sets the symmetry for a ramp waveform.
Suffix:
<m>
.
1..2
Parameters:
<RampSymmetry> Range: 0 to 100
Increment: 1
*RST: 50
Default unit: %
WGENerator<m>:FUNCtion:SQUare:DCYCle <SquareDutyCycle>
Sets the duty cycle for the generated square waveform.
Suffix:
<m>
.
1..2
Parameters:
<SquareDutyCycle> Range: 0.01 to 99.99 at minimum frequency, actual range
depends on the selected frequency
Increment: 1
*RST: 50
Default unit: %
Waveform generator (option R&S RTE-B6)