Remote control commands
R&S
®
RTE
1968User Manual 1326.1032.02 ─ 20
POWer:SWITching:GATE:TOFF:STOP...........................................................................1969
POWer:SWITching:GATE:TON:STARt............................................................................1969
POWer:SWITching:GATE:TON:STOP............................................................................ 1969
POWer:SWITching:RESult:ENERgy:ACTual?..................................................................1969
POWer:SWITching:RESult:ENERgy:AVG?......................................................................1969
POWer:SWITching:RESult:ENERgy:EVTCount?............................................................. 1969
POWer:SWITching:RESult:ENERgy:NPEak?.................................................................. 1969
POWer:SWITching:RESult:ENERgy:PPEak?.................................................................. 1969
POWer:SWITching:RESult:ENERgy:RMS?..................................................................... 1969
POWer:SWITching:RESult:ENERgy:STDDev?................................................................ 1969
POWer:SWITching:RESult:ENERgy:WFMCount?............................................................1969
POWer:SWITching:RESult:POWer:ACTual?................................................................... 1970
POWer:SWITching:RESult:POWer:AVG?........................................................................1970
POWer:SWITching:RESult:POWer:EVTCount?............................................................... 1970
POWer:SWITching:RESult:POWer:NPEak?.................................................................... 1970
POWer:SWITching:RESult:POWer:PPEak?.................................................................... 1970
POWer:SWITching:RESult:POWer:RMS?.......................................................................1970
POWer:SWITching:RESult:POWer:STDDev?..................................................................1970
POWer:SWITching:RESult:POWer:WFMCount?..............................................................1970
POWer:SWITching:AUTO <Autoscale>
Selects the scaling for the display of the results.
Parameters:
<Autoscale> AUTO | MANUAL
*RST: MANUAL
POWer:SWITching:EXECute
Starts the switching loss measurement.
Usage:
Event
Asynchronous command
POWer:SWITching:REPort:ADD
Adds the result to the report list.
Usage:
Event
POWer:SWITching:SWIFrequency <SwitchingFreq>
Sets the switching frequency.
Parameters:
<SwitchingFreq> Range: 1 to 500E+9
Increment: 1000
*RST: 10E+6
Default unit: Hz
Power analysis (option R&S RTE-K31)