Remote control commands
R&S
®
RTE
1973User Manual 1326.1032.02 ─ 20
POWer:RIPPle:RESult:PERiod[:ACTual]?.......................................................................1977
POWer:RIPPle:RESult:PERiod:AVG?.............................................................................1977
POWer:RIPPle:RESult:PERiod:EVTCount?.................................................................... 1977
POWer:RIPPle:RESult:PERiod:NPEak?.........................................................................1977
POWer:RIPPle:RESult:PERiod:PPEak?......................................................................... 1977
POWer:RIPPle:RESult:PERiod:RMS?............................................................................1977
POWer:RIPPle:RESult:PERiod:STDDev?.......................................................................1977
POWer:RIPPle:RESult:PERiod:WFMCount?...................................................................1977
POWer:RIPPle:RESult:STDDev[:ACTual]?..................................................................... 1978
POWer:RIPPle:RESult:STDDev:AVG?........................................................................... 1978
POWer:RIPPle:RESult:STDDev:EVTCount?...................................................................1978
POWer:RIPPle:RESult:STDDev:NPEak?........................................................................1978
POWer:RIPPle:RESult:STDDev:PPEak?........................................................................1978
POWer:RIPPle:RESult:STDDev:RMS?...........................................................................1978
POWer:RIPPle:RESult:STDDev:STDDev?......................................................................1978
POWer:RIPPle:RESult:STDDev:WFMCount?..................................................................1978
POWer:RIPPle:AUToscale <Autoscale>
Selects the scaling for the display of the results.
Parameters:
<Autoscale> AUTO | MANUAL
*RST: MANUAL
POWer:RIPPle:CURRent <TwoChMeas>
Activates or deactivates the input current.
Parameters:
<TwoChMeas> ON | OFF
*RST: ON
POWer:RIPPle:EXECute
Starts the ripple measurement.
Usage:
Event
POWer:RIPPle:FREQuency <SmpsFrequency>
Sets the SMPS switching frequency.
Parameters:
<SmpsFrequency> Range: 1 to 100E+9
Increment: 1
*RST: 1E+6
Default unit: Hz
Power analysis (option R&S RTE-K31)