Loading...
Remote control commands
R&S
®
RTE
1979User Manual 1326.1032.02 ─ 20
POWer:TRANsient:REPort:ADD....................................................................................1980
POWer:TRANsient:RESult[:ACTual]?.............................................................................1980
POWer:TRANsient:SIGHigh..........................................................................................1980
POWer:TRANsient:SIGLow...........................................................................................1980
POWer:TRANsient:TRGChannel................................................................................... 1980
POWer:TRANsient:TRGLevel........................................................................................1981
POWer:TRANsient:TRGSlope.......................................................................................1981
POWer:TRANsient:AUToscale <Autoscale>
Selects the scaling for the display of the results.
Parameters:
<Autoscale> AUTO | MANUAL
*RST: MANUAL
POWer:TRANsient:EXECute
Starts the transient response measurement.
Usage:
Event
POWer:TRANsient:FREQuency <SmpsFrequency>
Sets the SMPS switching frequency.
Parameters:
<SmpsFrequency> Range: 1 to 100E+6
Increment: 1
*RST: 1E+6
Default unit: Hz
POWer:TRANsient:HYSTeresis <ToleranceTube>
Specifies a tolerated error band for the signal level.
Parameters:
<ToleranceTube> Range: 0 to 50
Increment: 1
*RST: 10
Default unit: %
POWer:TRANsient:INPut <ThreeChMeas>
Activates or deactivates the input voltage.
Parameters:
<ThreeChMeas> ON | OFF
*RST: OFF
Power analysis (option R&S RTE-K31)