Figure 13-89: MDIO trigger event settings dialog
"Frame Start"
Sets the trigger to the start of frame (SOF) field. The start of frame
condition and the trigger instant is the end of the preamble.
Trigger pattern: preamble (32 bits "1")
There are no additional parameters to be specified.
"Frame Stop"
Sets the trigger to the end of frame (EOF) field. The trigger instant is
after the last data bit.
Trigger pattern: preamble (32 bits "1") + 32 bits "X"
There are no additional parameters to be specified.
MDIO (option R&S RTE-K55)