Protocol analysis
R&S
®
RTE
884User Manual 1326.1032.02 ─ 20
Normal Poll ← Trigger type
Triggers on a normal poll frame.
You can refine the trigger condition:
Set a frame ID pattern or a frame ID range to trigger only on frames that fulfill these
conditions.
See: "Frame ID" on page 887
Set an NM value expected in the frame.
See "NM" on page 889.
Set a CT value expected in the frame.
See: "CT" on page 889.
Set a DLC pattern or DLC pattern range to trigger only on frames that fulfill these
conditions.
See: "DLC" on page 888.
Set a data pattern condition to trigger only on frames that fulfill these conditions.
See: "Data" on page 888.
Set an index or index range to trigger only on frames that fulfill these conditions.
See: "Index" on page 889.
Sleep ← Trigger type
Triggers on a sleep frame.
You can refine the trigger condition:
Set an NM value expected in the frame.
See "NM" on page 889.
Set a CT value expected in the frame.
See: "CT" on page 889.
CXPI (option R&S