Usage: Asynchronous command
CALCulate:MATH<m>:FFT:GATE:ABSolute:STOP <Stop>
Defines the end value for the gate.
Suffix:
<m>
.
1..8
math waveform
Parameters:
<Stop> Range: -100E+24 to 100E+24
Increment: 0.01
*RST: 0.01
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:GATE:MODE <Mode>
Defines whether the gate settings are configured using absolute or relative values.
Suffix:
<m>
.
1..8
math waveform
Parameters:
<Mode> ABS | REL
*RST: ABS
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:GATE:RELative:STARt <RelativeStart>
Defines the starting value for the gate in percent.
Suffix:
<m>
.
1..8
math waveform
Parameters:
<RelativeStart> Range: 0 to 100
Increment: 0.1
*RST: 0
Default unit: %
Usage: Asynchronous command
CALCulate:MATH<m>:FFT:GATE:RELative:STOP <RelativeStop>
Defines the end value for the gate in percent.