Remote control commands
R&S
®
RTE
1490User Manual 1326.1032.02 ─ 20
V2
2.0 Volt (CAN_L HS / CAN_H LS)
V0
Ground
MANual
Manual setting of user-defined values with BUS<m>:CAN:DATA:
THReshold.
*RST: V25
BUS<m>:CAN:BITRate
<Bitrate>
For CAN buses, the "Bit rate" sets the number of transmitted bits per second.
For CAN FD buses, this parameter is called "Arbitration rate" and sets the bit rate of
the arbitration phase.
The maximum bit rate for High Speed CAN is 1 Mbit/s. The bit rate is uniform and fixed
for a given CAN or CAN FD bus.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<Bitrate> Range: 100 to 5E+6
Increment: 1
*RST: 100E+3
Default unit: bps
BUS<m>:CAN:FDATa:ENABle <CANFDEnabled>
Enables the CAN FD protocol configuration.
The setting is available in CAN FD option R&S RTE-K9.
Suffix:
<m>
.
1..4
Parameters:
<CANFDEnabled> ON | OFF
*RST: ON
BUS<m>:CAN:FDATa:DBITrate <FlexDatBitrate>
Sets the bit rate of the data phase. The data rate can be higher than the arbitration