Remote control commands
R&S
®
RTE
1491User Manual 1326.1032.02 ─ 20
Parameters:
<FlexDatBitrate> Range: 100 to 15E+6
Increment: 1
*RST: 1E+6
Default unit: bps
BUS<m>:CAN:FDATa:SAMPlepoint <FlexDatSmpPt>
BUS<m>:CAN:SAMPlepoint <SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
Alternatively, you can set the sample point with BUS<m>:CAN:T1Segment and
BUS<m>:CAN:T2Segment.
For CAN FD signals, BUS<m>:CAN:SAMPlepoint defines the synchronization of the
arbitration phase, and BUS<m>:CAN:FDATa:SAMPlepoint defines the synchroniza-
tion of the data phase.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<FlexDatSmpPt>
<SamplePoint>
Range: 12 to 96 if number of segments is 24. The range
reduces if the signal has fewer segments.
Increment: 5
*RST: 66
Default unit: %
BUS<m>:CAN:FDATa:T1Segment <FlexDatTimeSeg1>
BUS<m>:CAN:T1Segment <TimeSeg1>
Sets the number of time quanta before the sample point (T1Segment). T1Segment
comprises the segments Synch_seg, Prop_seg, and Phase_seg1 which are specified
in the CAN standard.
Make sure to set also BUS<m>:CAN:T2Segment for correct definition of the sample
point. Alternatively, you can use BUS<m>:CAN:SAMPlepoint.
See also: "Synchronization: Sample point, Time segments, Jump width" on page 565
For CAN FD signals, BUS<m>:CAN:T1Segment defines the synchronization of the
arbitration phase, and BUS<m>:CAN:FDATa:T1Segment defines the synchronization
of the data phase.
Suffix:
<m>
.
1..4
Parameters:
<FlexDatTimeSeg1>
<TimeSeg1>
Time quanta
Range: 3 to 23
Increment: 1
*RST: 6.6