Remote control commands
R&S
®
RTE
1664User Manual 1326.1032.02 ─ 20
SEARch:TRIGger:ETHernet:FRAMe:SCONdition
<SearchName>,<SrcAddrOperator>
SEARch:TRIGger:ETHernet:FRAMe:SCONdition? <SearchName>
Defines the operator to search a specific source address within a frame.
Parameters:
<SrcAddrOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater Than,
Greater than or equal. These conditions require a destination
address to be set with SEARch:TRIGger:ETHernet:FRAMe:
SMIN.
INRange | OORange
In range, Out of range. Set the minimum and maximum value of
the range with SEARch:TRIGger:ETHernet:FRAMe:SMIN
and SEARch:TRIGger:ETHernet:FRAMe:SMAX.
*RST:
EQUal
Parameters for setting and query:
<SearchName> String parameter
SEARch:TRIGger:ETHernet:FRAMe:SMIN <SearchName>,<SrcAddrPattMin>
SEARch:TRIGger:ETHernet:FRAMe:SMIN? <SearchName>
Defines a source address, or sets the start value of a source address range.
Parameters:
<SrcAddrPattMin> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName> String parameter
SEARch:TRIGger:ETHernet:FRAMe:SMAX <SearchName>,<SrcAddrPattMax>
SEARch:TRIGger:ETHernet:FRAMe:SMAX? <SearchName>
Sets the end value of a source address range, if SEARch:TRIGger:ETHernet:
FRAMe:SCONdition is set to INRange or OORange.
Parameters:
<SrcAddrPattMax> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName> String parameter
Protocols