Remote control commands
R&S
®
RTE
1929User Manual 1326.1032.02 ─ 20
Parameters:
<Deviation> Range: 1E-3 to 10E+6
Increment: 1
*RST: 1000
Default unit: Hz
WGENerator<m>:MODulation:FM:FREQuency <Frequency>
Sets the frequency of the modulation waveform for frequency modulation, if
WGENerator<m>:MODulation:TYPE is set to FM.
Suffix:
<m>
.
1..2
Parameters:
<Frequency> Range: 1E-3 to 1E+6
Increment: 1
*RST: 1000
Default unit: Hz
WGENerator<m>:MODulation:FM:SYMMetry <RampSymmetry>
Sets the symmetry, the percentage of time the ramp modulation waveform is rising, for
frequency modulation, if WGENerator<m>:MODulation:TYPE is set to FM.
Suffix:
<m>
.
1..2
Parameters:
<RampSymmetry> Range: 0 to 100
Increment: 1
*RST: 50
Default unit: %
WGENerator<m>:MODulation:FM[:FUNCtion] <SignalType>
Sets the type of the modulation signal for the frequency modulation, if
WGENerator<m>:MODulation:TYPE is set to FM.
Suffix:
<m>
.
1..2
Parameters:
<SignalType> SINusoid | SQUare | RAMP
*RST: SINusoid
WGENerator<m>:MODulation:FSK:FONE <Frequency1>
Sets the frequency of the carrier waveform, if WGENerator<m>:MODulation:TYPE
is set to FSK.