Protocol analysis
R&S
®
RTE
717User Manual 1326.1032.02 ─ 20
Make sure that:
In the [PROTOCOL] > "Decode" tab:
The correct "Protocol" is selected.
The data sources of the serial bus are channel signals.
In the "Trigger" > "Setup" tab:
The trigger "Sequence" = "A only".
The trigger "Source" = "Serial bus".
The correct "Serial bus" is selected.
Type
Selects the trigger type for 100BASE-T1 analysis.
Remote command:
TRIGger<m>:HBTO:TYPE on page 1676
Frame Start ← Type
Triggers on the start of frame.
MAC Frame ← Type
Triggers on a Media Access Control (MAC) frame. You can specify:
Destination address
Source address
Length/Type
Frame check
Data
Index
The frame contains addresses of the devices and MAC control information that define
how to go about transmitting and receiving frames.
IDLE ← Type
Triggers on an idle frame. The frame is used for clock synchronization.
Error ← Type
Triggers on the specified error frame.
Ethernet 100BASE-T1 (option R&S
RTE-57)

Table of Contents