Regs, V2.0
Table 18-26 Address Map of RBCU
Short Name Description Address Access Mode Reset Value
Read Write
Remote Peripheral Bus Control Unit (RBCU)
Reserved F010 0000
H
-
F010 0004
H
BE BE
RBCU_ID RBCU Module
Identification Register
F010 0008
H
U, SV BE 0000 6AXX
H
Reserved F010 000C
H
BE BE
RBCU_
CON
RBCU Control Register F010 0010
H
U, SV SV 4009 FFFF
H
Reserved F010 0014
H
-
F010 001C
H
BE BE
RBCU_
ECON
RBCU Error Control
Capture Register
F010 0020
H
U, SV SV 0000 0000
H
RBCU_
EADD
RBCU Error Address
Capture Register
F010 0024
H
U, SV SV 0000 0000
H
RBCU_
EDAT
RBCU Error Data Capture
Register
F010 0028
H
U, SV SV 0000 0000
H
Reserved F010 002C
H
BE BE
RBCU_
DBCNTL
RBCU Debug Control
Register
F010 0030
H
U, SV SV 0000 7003
H
RBCU_
DBGRNT
RBCU Debug Grant Mask
Register
F010 0034
H
U, SV SV 0000 FFFF
H
RBCU_
DBADR1
RBCU Debug Address 1
Register
F010 0038
H
U, SV SV 0000 0000
H
RBCU_
DBADR2
RBCU Debug Address 2
Register
F010 003C
H
U, SV SV 0000 0000
H
RBCU_
DBBOS
RBCU Debug Bus
Operation Signals
Register
F010 0040
H
U, SV SV 0000 0000
H
RBCU_
DBGNTT
RBCU Debug Trapped
Master Register
F010 0044
H
U, SV BE FFFF FFFF
H
RBCU_
DBADRT
RBCU Debug Trapped
Address Register
F010 0048
H
U, SV BE 0000 0000
H