EasyManuals Logo

Infineon Technologies TC1796 User Manual

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #497 background imageLoading...
Page #497 background image
TC1796
System Units (Vol. 1 of 2)
General Purpose I/O Ports and Peripheral I/O Lines
User’s Manual 10-45 V2.0, 2007-07
Ports, V2.0
10.6.3 Port 3 Registers
The following registers are available on Port 3:
Note: The complete address map of Port 3 is described in Table 18-12 on Page 18-25
of this TC1796 System Units (Vol. 1 of 2) User’s Manual.
Table 10-14 Port 3 Registers
Register
Short Name
Register Long Name Offset
Address
Description
see
P3_OUT Port 3 Output Register 0000
H
Page 10-13
P3_OMR Port 3 Output Modification Register 0004
H
Page 10-14
P3_IOCR0 Port 3 Input/Output Control Register 0 0010
H
Page 10-7
P3_IOCR4 Port 3 Input/Output Control Register 4 0014
H
Page 10-8
P3_IOCR8 Port 3 Input/Output Control Register 8 0018
H
Page 10-8
P3_IOCR12 Port 3 Input/Output Control Register 12 001C
H
Page 10-9
P3_IN Port 3 Input Register 0024
H
Page 10-17
P3_PDR Port 3 Pad Driver Mode Register 0040
H
Page 10-46
1)
1) This register is listed here in the Port 3 section because they differ from the general port register description
given in Section 10.2.
P3_ESR Port 3 Emergency Stop Register 0050
H
Page 10-16

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infineon Technologies TC1796 and is the answer not in the manual?

Infineon Technologies TC1796 Specifications

General IconGeneral
BrandInfineon Technologies
ModelTC1796
CategoryController
LanguageEnglish