TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual 23-57 V2.0, 2007-07
MLI, V2.0
Note: The number of SRx outputs of an MLI module and their connection to other
modules depends on the implementation of the MLI module in the specific product.
23.2.5 Transmitter Events
The MLI transmitter can generate the following MLI events:
Table 23-7 MLI Transmitter Events
Events Events combined to See
Parity Error Parity/Time-out Error Page 23-58
Time-out Error
Normal Frame Sent in Pipe 0 Normal Frame Sent in Pipe 0 Page 23-58
Normal Frame Sent in Pipe 1 Normal Frame Sent in Pipe 1
Normal Frame Sent in Pipe 2 Normal Frame Sent in Pipe 2
Normal Frame Sent in Pipe 3 Normal Frame Sent in Pipe 3
Command Frame Sent in Pipe 0 Command Frame Sent Page 23-59
Command Frame Sent in Pipe 1
Command Frame Sent in Pipe 2
Command Frame Sent in Pipe 3