EasyManua.ls Logo

Infineon Technologies TC1796 - 23.5.4.2 Input;Output Control Register

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual 23-133 V2.0, 2007-07
MLI, V2.0
23.5.4.2 Input/Output Control Register
The following pages describe all IOCR registers that contain MLI0/MLI1 related
input/output control bit fields. Shaded bits and bit fields are “don’t care” for MLI0/MLI1
I/O port control purposes.
Table 23-12 PCx Coding
PCx[3:0] I/O Output
Characteristics
Selected Pull-up/Pull-down/
Selected Output Function
0X00
B
Input No pull device connected
0X01
B
Pull-down device connected
0X10
B
1)
1) This bit field value is default after reset.
Pull-up device connected
0X11
B
No pull device connected
1001
B
Output Push-pull Output function ALT1
1101
B
Open-drain Output function ALT1
1010
B
Push-pull Output function ALT2
1110
B
Open-drain Output function ALT2
1011
B
Push-pull Output function ALT3
1111
B
Open-drain Output function ALT3
P1_IOCR0
Port 1 Input/Output Control Register 0
(10
H
) Reset Value: 2020 2020
H
31 28 27 24 23 20 19 16 15 12 11 8 7 4 3 0
PC3 0 PC2 0 PC1 0 PC0 0
rw r rw r rw r rw r
Field Bits Type Description
PC3 [31:28] rw Port Input/Output Control for Port 1 Pins 0-3
1)
Port input/output control for P1.3/TREADY0B
1) Coding of bit field see Table 23-12. Shaded bits and bit fields are “don’t care” for MLI I/O port control.