TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual 5-69 V2.0, 2007-07
SCU, V2.0
5.13.3 Device Identification Registers
The SCU Module Identification Register ID contains read-only information about the
SCU module version.
SCU_ID
SCU Module Identification Register
(F0000008
H
) Reset Value: 002C C0XX
H
31 16 15 8 7 0
MODNUM MODTYPE MODREV
rrr
Field Bits Type Description
MODREV [7:0] r Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE [15:8] r Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM [31:16] r Module Number Value
This bit field defines the module identification number for
the SCU: 002C
H
MANID
Manufacturer Identification Register
(F0000070
H
) Reset Value: 0000 1820
H
31 16 15 5 4 0
0 MANUF DEPT
rrr
Field Bits Type Description
DEPT [4:0] r Department Identification Number
=00
H
: indicates the Automotive & Industrial
microcontroller department within Infineon Technologies.