TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual 25-75 V2.0, 2007-07
ADC, V2.0
25.2.6 Auto-Scan Registers
SCN
Auto-Scan Control Register (124
H
) Reset Value: 0000 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
GRPC 0
rw r
1514131211109876543210
SRQ
15
SRQ
14
SRQ
13
SRQ
12
SRQ
11
SRQ
10
SRQ
9
SRQ
8
SRQ
7
SRQ
6
SRQ
5
SRQ
4
SRQ
3
SRQ
2
SRQ
1
SRQ
0
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw
Field Bits Type Description
SRQn
(n = 0-15)
nrwAuto-Scan Request for Channel n
SRQn determines whether or not channel n
participates in an auto-scan sequence.
0
B
Channel n does not participate in an auto-
scan sequence.
1
B
Channel n participates in an auto-scan
sequence.
Note: Bits SRQn maintain their values after auto-
scan control bit field CON.SCNM is cleared.