EasyManua.ls Logo

Infineon Technologies TC1796 - 24.3.1 Identification Register

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-154 V2.0, 2007-07
GPTA, V2.0
24.3.1 Identification Register
The Module Identification Register ID contains read-only information about the GPTA
module version.
GPTA0_ID
GPTA0 Module Identification Register
(008
H
) Reset Value: 0029 C0XX
H
GPTA1_ID
GPTA1 Module Identification Register
(008
H
) Reset Value: 0029 C0XX
H
31 16 15 8 7 0
MODNUM MODTYPE MODREV
rrr
Field Bits Type Description
MODREV [7:0] r Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE [15:8] r Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM [31:16] r Module Number Value
This bit field defines the module identification number for
the GPTA: 0029
H

Table of Contents