General Purpose Timer Array (GPTA)
User’s Manual 24-154 V2.0, 2007-07
GPTA, V2.0
24.3.1 Identification Register
The Module Identification Register ID contains read-only information about the GPTA
module version.
GPTA0_ID
GPTA0 Module Identification Register
(008
H
) Reset Value: 0029 C0XX
H
GPTA1_ID
GPTA1 Module Identification Register
(008
H
) Reset Value: 0029 C0XX
H
31 16 15 8 7 0
MODNUM MODTYPE MODREV
rrr
Field Bits Type Description
MODREV [7:0] r Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE [15:8] r Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM [31:16] r Module Number Value
This bit field defines the module identification number for
the GPTA: 0029
H