TC1796
System Units (Vol. 1 of 2)
Peripheral Control Processor (PCP)
User’s Manual 11-127 V2.0, 2007-07
PCP, V2.0
FPI Bus error as the PCP’s interface to the FPI Bus becomes reset.
Therefore, it is generally not recommended to use the PCP soft reset capability in
a PCP application program. A PCP hard reset should be generated instead.
11.14.4 BCOPY Instruction
In the TC1796, the BCOPY instruction can be used to perform burst transfers (2, 4, or
8 words) with DMI memories (Local data RAM and Dual-port RAM) and the PCP
memories. Other internal and external memories can be accessed using a burst size of
2 words only (CNT0 = 10