EasyManuals Logo

Infineon Technologies TC1796 User Manual

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1968 background imageLoading...
Page #1968 background image
TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual 25-37 V2.0, 2007-07
ADC, V2.0
25.1.5 Reference Voltages (V
AREF
and V
AGND
)
The digital result of a conversion represents the analog input as a fraction of the
reference (V
AREF
- V
AGND
) in steps of 2
-n
by n-bit resolution:
Result = 2
n
× (V
AIN
- V
AGND
) / (V
AREF
- V
AGND
)(25.5)
The ADC module offers the choice of four selectable reference voltages V
AREF
[0] to
V
AREF
[3]. The reference voltage can independently be selected for each analog channel
via the respective bit field CHCONn.REF. V
AREF
[0] corresponds to the positive reference
voltage V
AREF
and is used for self calibration of the A/D Converter. Therefore, it must be
stable during all conversions, even for those that use another reference voltage.
The reference voltages must fulfill the following specifications:
V
AREF
[3:0] V
DDM
+ 0.05 V; V
DDM
3.3 V (25.6)
A conversion with low reference voltage affects the accuracy of the A/D Converter. The
TUE of an A/D Converter that is operated at a reduced positive reference voltage can be
evaluated according to the following equations:
TUE |
A
TUE |
B
= K × TUE |
A
, (K 1) (25.7)
with factor K as:
V
AREF
|
A
V
AREF
|
B
= 1/K × V
AREF
|
A
(25.8)
where
V
AREF
|
A
: minimum positive reference voltage range is specified
for 0 V V
AREF
V
DDM
+ 0.05 V
V
AREF
|
B
: positive reference voltage, which is below the specified range
•TUE |
A
: total unadjusted error for reference voltages within the specified range
•TUE |
B
: total unadjusted error for reference voltages below the specified range
Note: All unused analog input pins must be connected to a fixed potential either V
AGND
or V
AREF
[0] to avoid disturbance of active analog inputs.
Note: It is not recommended in general to set V
AREF
below 50% of V
DDM
.
Note: The analog input voltages V
AIN
must be in the range between V
AGND
and the
selected V
AREF
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infineon Technologies TC1796 and is the answer not in the manual?

Infineon Technologies TC1796 Specifications

General IconGeneral
BrandInfineon Technologies
ModelTC1796
CategoryController
LanguageEnglish