24.2.4 Input/Output Line Sharing Unit (IOLS)
The I/O Line Sharing Unit allows the 56 inputs and 112 outputs of the GPTA unit to be
routed with high flexibility between I/O lines, output lines, clock inputs, other on-chip
peripherals and other GPTA cells. The GPTA module provides a total of 56 input lines
and 112 output lines, assigned to seven I/O groups IOG[6:0] and seven output groups
OG[6:0].
Figure 24-60 Input/Output Line Sharing Unit Overview