TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual 25-73 V2.0, 2007-07
ADC, V2.0
25.2.5 External Trigger Registers
EXTC
External Trigger Control Register (090
H
) Reset Value: 0000 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
0
r
1514131211109876543210
ETC
CH
15
ETC
CH
14
ETC
CH
13
ETC
CH
12
ETC
CH
11
ETC
CH
10
ETC
CH
9
ETC
CH
8
ETC
CH
7
ETC
CH
6
ETC
CH
5
ETC
CH
4
ETC
CH
3
ETC
CH
2
ETC
CH
1
ETC
CH
0
rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw rw
Field Bits Type Description
ETCHn
(n = 0-15)
nrwExternal Trigger Control for Channel n
ETCHn specifies if a conversion request is
triggered on an event on the selected input line
(including gating) for channel n.
0
B
No conversion request is triggered for
channel n.
1
B
A conversion request is triggered for
channel n
0 [31:16] r Reserved
Read as 0; should be written with 0.