Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual 21-24 V2.0, 2007-07
MSC, V2.0
Figure 21-16 16-Bit Upstream Reception
Data Reception without Address Field
Frame reception for a 12-bit data frame is selected by USR.UFT = 0. The reception
scheme is comparable with that of the 16-bit data frame reception but there are a few
differences:
The upstream counter USR.UC is initially loaded with 01100
B
.
The received frame content is always stored in register UD0.
Bit field UD0.LABF is always loaded with 00
B
when the frame is stored.
MCT05810
D0 D1 D7D6
Start
P
16-Bit Upstream Data Frame
A3A2 Stop Stop
16151413121110 4321
0 0
A1
5
Sampling Shifting
A0
SI
Receive
Enabled
f
BR
UC