TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-50 V2.0, 2007-07
GPTA, V2.0
The previous examples show that the result bit to select for observation (R
3
) corresponds
to the comparator window’s size (k = 3).
Considering the case in which the period is not a multiple of 2, choose a comparator
window whose width is between 1 and 2 times the timer period:
2
k
< Period 2 × 2
k
(24.2)
In no case may the comparator window be equal to or greater than twice the period.