TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-135 V2.0, 2007-07
GPTA, V2.0
Variables
Input, Local, Output variables of the cell (I, L, O)
Name k = [0 to 31] for GTC
m = [0, 1] for GT
Short
Name
(*)GTC
Used
(ILO)
Comment
GTm.Timer_Greater_Equal_Comp TGEm I Timer is greater or equal
GTm.Timer_Event TEVm I Signal for timer change
GTm.Timer *TIMm I Timer value
GTCk.Data_In *DINk I Data input from input multiplexer
GTCk.Output_Mode_In *M1Ik
*M0Ik
I Link signals from preceding cell
GTCk.X_Write_Access *XWA L Indicates that GTCk.X was
modified
GTCk.Event *EVE L Local event
GTCk.Signal_Input *INS L Qualified input signal
GTCk.Service_Request_Trigger *SQSk O Service request line
GTCk.Data_Out *DOUk O Data output for output
multiplexer
GTCk.Output_Mode_Out *M1Ok
*M0Ok
O Link signals to following cell

Table of Contents