TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-164 V2.0, 2007-07
GPTA, V2.0
GPTA0_DCMCOVk (k = 0-3)
GPTA0 Duty Cycle Measurement Capture/Compare Register k
(08C
H
+k*10
H
) Reset Value: 0000 0000
H
GPTA1_DCMCOVk (k = 0-3)
GPTA1 Duty Cycle Measurement Capture/Compare Register k
(08C
H
+k*10
H
) Reset Value: 0000 0000
H
31 24 23 0
0COV
rrwh
Field Bits Type Description
COV [23:0] rwh Capture/Compare Register Value of DCMk
0 [31:24] r Reserved
Read as 0; should be written with 0.