TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-207 V2.0, 2007-07
GPTA, V2.0
DCM00C,
DCM01C,
DCM02C,
DCM03C
2,
5,
8,
11
rwh DCMk
1)
Compare Event Service Request State
0
B
No service is requested.
1
B
Service is requested due to a compare event
occurred in DCMk unit (k = 0-3).
PLL 12 rwh Counter Service Request State for PLL
0
B
No service is requested.
1
B
Service is requested because the counter for
the number remaining output pulses
decremented to 0.
GT00 13 rwh GT0 Timer Service Request State
0
B
No service is requested.
1
B
Service is requested due to a GT0 timer
overflow.
GT01 14 rwh GT1 Timer Service Request State
0
B
No service is requested.
1
B
Service is requested due to a GT1 timer
overflow.
0 [31:15] r Reserved
Read as 0; should be written with 0.
1) k = 0-3; k = 0 refers to DCM00R, DCM00P, or DCM00C; k = 1 refers to DCM01R, DCM01P, or DCM01C;
k = 2 refers to DCM02R, DCM02P, or DCM02C; k = 3 refers to DCM03R, DCM03P, or DCM03C.
Field Bits Type Description

Table of Contents