TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual 25-91 V2.0, 2007-07
ADC, V2.0
CIREN 15 rw Cancel, Inject and Repeat Enable
This bit enables the Cancel, Inject and Repeat
feature.
0
B
Cancel, Inject and Repeat feature is disabled.
1
B
Cancel, Inject and Repeat feature is enabled.
CINREQ 31 rw Channel Injection Request
This bit is the request bit for Channel Injection. It is
automatically cleared after the requested conversion
is injected.
0
B
No Channel Injection requested
1
B
Channel Injection requested
Note: Clearing bit AP.CHP causes bit
CHIN.CINREQ to be cleared.
0 [5:4],
[14:11],
[30:16]
r Reserved
Read as 0; should be written with 0.