EasyManuals Logo

Infineon Technologies TC1796 User Manual

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2057 background imageLoading...
Page #2057 background image
TC1796
Peripheral Units (Vol. 2 of 2)
Fast Analog-to-Digital Converter (FADC)
User’s Manual 26-6 V2.0, 2007-07
FADC, V2.0
FAINxN = 0 V: FADC conversion result is 768
FAINxN = 3.3 V: FADC conversion result is 256
To cover the full range of the measurement result in this single-ended measurement
mode, a gain of 2 must be selected (ACRx.GAIN = 01
B
). With gain = 2, the FADC will
deliver conversion results as follows:
FAINxN = 0 V: FADC conversion result is 1023
FAINxN = 3.3 V: FADC conversion result is 0
The voltage at the disconnected positive analog input FAINxP has no influence on the
conversion result.
Configuration 2 (ACRx.ENP = 1 and ACRx.ENN = 0)
This configuration enables the single-ended measurement mode for FAINxP -
V
VAREF
/2.
The negative analog input FAINxN is disconnected and in a high impedance state. The
positive analog input FAINxP is connected to the channel amplifier (input impedance is
determined by Rp). The negative input of the channel amplifier is connected to V
FAREF
/2
(1.65 V with V
FAREF
= 3.3 V). If the voltage at the positive input FAINxP varies, the FADC
will deliver conversion results as follows (gain = 1 selected by ACRx.GAIN = 00
B
):
FAINxP = 0 V: FADC conversion result is 256
FAINxP = 3.3 V: FADC conversion result is 768
To cover the full range of the measurement result in this single-ended measurement
mode, a gain of 2 must be selected (ACRx.GAIN = 01
B
). With gain = 2, the FADC will
deliver conversion results as follows:
FAINxP = 0 V: FADC conversion result is 0
FAINxP = 3.3 V: FADC conversion result is 1023
The voltage at the disconnected negative analog input FAINxN has no influence on the
conversion result.
Configuration 3 (ACRx.ENP = ACRx.ENN = 1)
This configuration enables the differential measurement mode for FAINxP - FAINxN.
Both analog inputs, FAINx.N and FAINxP, are connected to the channel amplifier inputs.
Their impedances are determined by Rn and Rp. The full measurement range is
available.
Table 26-1 provides a summary of the conversion results that are available at the
different measurement modes. This table assumes a reference voltage of
V
FAREF
=3.3V.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infineon Technologies TC1796 and is the answer not in the manual?

Infineon Technologies TC1796 Specifications

General IconGeneral
BrandInfineon Technologies
ModelTC1796
CategoryController
LanguageEnglish