Page #326 background image
TC1796
System Units (Vol. 1 of 2)
On-Chip System Buses and Bus Bridges
User’s Manual 6-33 V2.0, 2007-07
Buses, V2.0
greater or equal to SBCU_DBADR1.
ONG = 1 means that the grant debug trigger is enabled.
CONCOM[2:0] = 101
B
means that the address trigger is created by address trigger 1
OR address trigger 2 (CONCOM1 = 0), and that the grant trigger is ANDed with the
address trigger (CONCOM0 = 1), and that the signal status trigger is ANDed with the
address trigger (CONCOM2 = 1).
RA = 1 means that the BCU breakpoint logic is rearmed.
4. Writing SBCU_DBGRNT = FFFFFFF7
H
:
means that the grant trigger for the SPB bus master PCP is enabled.
5. Writing SBCU_DBBOS is “don’t care”. No signal trigger for SVM, WR, or RD is
generated.