TC1796
System Units (Vol. 1 of 2)
Program Memory Unit
User’s Manual 7-48 V2.0, 2007-07
PMU, V2.0
RPROIN 18 rh Read Protection Installed
This flag indicates whether read protection is
correctly installed. This bit is updated only if a
modified read protection installation is detected at a
reset operation.
0
B
No read protection installed.
1
B
Read protection is correctly installed.
RPRODIS 19 rh Read Protection Disable State
This flag indicates whether read protection is
temporarily disabled. RPRODIS is cleared by any
reset operation and by the Resume Protection
command.
0
B
The read protection is installed and enabled, or
it is not installed (default after reset).
1
B
The read and global write protection is
temporarily disabled. External Flash read as
well as programming or erase on not separately
write-protected sectors is possible.
WPROIN0 21 rh UCB0 Write Protection Installed
This flag indicates whether sector write protection in
UCB0 is correctly installed and confirmed. This bit is
updated only if a modified UCB0 protection
installation is detected at a reset operation.
0
B
No write protection installed in UCB0.
1
B
Sector write protection is correctly installed in
UCB0.
WPROIN1 22 rh UCB1 Write Protection Installed
This flag indicates whether sector write protection in
UCB1 is correctly installed and confirmed. This bit is
updated only if a modified UCB1 protection
installation is detected at a reset operation.
0
B
No write protection installed in UCB1.
1
B
Sector write protection is correctly installed in
UCB1.
Field Bits Type Description