TC1796
System Units (Vol. 1 of 2)
Program Memory Unit
User’s Manual 7-50 V2.0, 2007-07
PMU, V2.0
VER 31 rh Verify Error
This flag indicates whether a Flash page has been
correctly programmed. VER is cleared by any reset
operation and by the Clear Status command.
0
B
A Flash page is correctly programmed. All
programmed 1 bits have a full quality.
1
B
A Flash page programming verify error has
been detected. A correction of weak bits by the
programming algorithm was unsuccessful
during the last programming operation.
Note: There is no interrupt generated when VER is
set.
0 17, 20,
24, 27,
[30:29]
r Reserved
Read as 0.
Field Bits Type Description