EasyManuals Logo

Infineon Technologies TC1796 User Manual

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #421 background imageLoading...
Page #421 background image
TC1796
System Units (Vol. 1 of 2)
Data Memory Unit
User’s Manual 8-9 V2.0, 2007-07
DMU, V2.0
subsequent fast accesses for data with high locality, and un-cached faster accesses for
data with low locality.
Write Transactions
When a write transaction hits into the read buffer, the buffer content is invalidated. This
feature also can be used to flush the buffer contents.
Read-Modify-Write Transactions
Read-modify-write transaction always will be forwarded to the PLMB. They will not effect
the buffer content at all (no caching, no invalidation). This implies that read-modify-write
operations should be done to non-cached areas only.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Infineon Technologies TC1796 and is the answer not in the manual?

Infineon Technologies TC1796 Specifications

General IconGeneral
BrandInfineon Technologies
ModelTC1796
CategoryController
LanguageEnglish