EasyManua.ls Logo

Infineon Technologies TC1796 - Page 927

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC1796
System Units (Vol. 1 of 2)
System Timer
User’s Manual 15-10 V2.0, 2007-07
STM, V2.0
The STM Module Identification Register ID contains read-only information about the
STM module version.
RMC [10:8] rw Clock Divider in Run Mode
000
B
No clock signal f
STM
generated
001
B
Clock signal f
STM
= f
SYS
selected
(default after reset)
010
B
Clock signal f
STM
/ 2 selected
011
B
Clock signal f
STM
/ 3 selected
...
B
...
111
B
Clock signal f
STM
/ 7 selected
Note: This bit field is not affected by a hardware reset
operation (HDRST =0).
0 [7:6],
[31:11]
r Reserved
Read as 0; should be written with 0.
STM_ID
STM Module Identification Register (08
H
) Reset Value: 0000 C0XX
H
31 16 15 8 7 0
MODNUM MODTYPE MODREV
rrr
Field Bits Type Description
MODREV [7:0] r Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE [15:8] r Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM [31:16] r Module Number Value
This bit field defines the module identification number for
the STM: 0000
H
Field Bits Type Description

Table of Contents