Remote control commands
R&S
®
RTE
1193User Manual 1326.1032.02 ─ 20
CUSTom
User-defined signal. Configure the signal using:
TRIGger<m>:TV:CUSTom:SCANmode
TRIGger<m>:TV:CUSTom:STYPe
TRIGger<m>:TV:CUSTom:LDURation
TRIGger<m>:TV:CUSTom:SDURation
PAL | PALM | NTSC | SECam
SDTV standards. PALM = PAL-M
PxxxxLyyHZ
HDTV standards using progressive scanning (P). xxxx indicates
the number of active lines, yy is the frame rate.
IxxxxLxxHZ
HDTV standards using interlaced scanning (I). xxxx indicates the
number of active lines, yy is the field rate.
P1080L24HZSF
1080p/24sF is a HDTV standard using progressive segmented
frame scanning.
*RST:
PAL
Usage: Asynchronous command
TRIGger<m>:TV:MODE <Mode>
Selects the lines or fields on which the instrument can trigger. Available modes depend
on the scanning system.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<Mode> ALL | ODD | EVEN | ALINe | LINE
ALL
All fields, triggers on the frame start (progressive scanning) or
field start (interlaced and progressive segmented frame scan-
ning)
ODD | EVEN
Only available for interlaced scanning and progressive segmen-
ted frame scanning. Triggers on the field start of the odd or even
field.
ALINe
All lines, triggers on all line starts.
LINE
Triggers on a specified line. To set the line number, use
TRIGger<m>:TV:LINE. For NTSC signals, set also the field
with TRIGger<m>:TV:LFIeld.
*RST:
ALL
Usage: Asynchronous command
Trigger