Remote control commands
R&S
®
RTE
1296User Manual 1326.1032.02 ─ 20
<MeasType> param-
eter value (remote
control)
Measurement (man-
ual operation)
Description/Result
FER Frame error rate Sum of all frames with errors divided by all frames within
the acquisition window
CFER Consecutive frame
error rate
Measures the frame error rate
MEASurement<m>:PROTocol:F2FRame:FLDFrom......................................................... 1296
MEASurement<m>:PROTocol:F2FRame:FLDTo............................................................. 1296
MEASurement<m>:PROTocol:F2FRame:FRMFrom........................................................ 1297
MEASurement<m>:PROTocol:F2FRame:FRMTo.............................................................1297
MEASurement<m>:PROTocol:F2FRame:VALFrom..........................................................1297
MEASurement<m>:PROTocol:F2FRame:VALTo..............................................................1297
MEASurement<m>:PROTocol:FLDValue:FLD................................................................. 1298
MEASurement<m>:PROTocol:FLDValue:FRM................................................................ 1298
MEASurement<m>:PROTocol:FLDValue:TRCK.............................................................. 1298
MEASurement<m>:PROTocol:FLDValue:VAL................................................................. 1298
MEASurement<m>:PROTocol:MBITrate:FLD.................................................................. 1299
MEASurement<m>:PROTocol:MBITrate:FRM................................................................. 1299
MEASurement<m>:PROTocol:MBITrate:VAL.................................................................. 1299
MEASurement<m>:PROTocol:SBITrate:FLD...................................................................1299
MEASurement<m>:PROTocol:SBITrate:FRM..................................................................1299
MEASurement<m>:PROTocol:SBITrate:VAL...................................................................1300
MEASurement<m>:PROTocol:T2FRame:DIRection.........................................................1300
MEASurement<m>:PROTocol:T2FRame:FLD.................................................................1300
MEASurement<m>:PROTocol:T2FRame:FRM................................................................1300
MEASurement<m>:PROTocol:T2FRame:VALue..............................................................1301
MEASurement<m>:PROTocol:F2FRame:FLDFrom <FieldName>
Sets the type of field for the start frame of the frame to frame protocol measurement.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.
Parameters:
<FieldName>
MEASurement<m>:PROTocol:F2FRame:FLDTo <FieldName>
Sets the type of field for the end frame of the frame to frame protocol measurement.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"