Remote control commands
R&S
®
RTE
1881User Manual 1326.1032.02 ─ 20
Parameters:
<DLCMax>
TRIGger<m>:CXPI:DLC:MIN <DLCMin>
Specifies a DLC pattern, or sets the start value of a pattern range.
Suffix:
<m>
.
1..3
Parameters:
<DLCMin>
TRIGger<m>:CXPI:ERRor:CRC
<ErrorCRC>
Triggers on a cyclic redundancy check error, if TRIGger<m>:CXPI:TYPE is set to
ERRor.
The transmitting node calculates the cyclic redundancy check (CRC) value of a frame
and stores it into the CRC field of the frame. CRC error occurs when this CRC field
value differs from the value calculated by the receiving node.
Suffix:
<m>
.
1..3
Parameters:
<ErrorCRC> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:DLC <ErrorDLC>
Triggers on a data length code (DLC) error, if TRIGger<m>:CXPI:TYPE is set to
ERRor.
DLC error occurs when the value of the DLC field is different from the data byte field
value.
Suffix:
<m>
.
1..3
Parameters:
<ErrorDLC> ON | OFF
*RST: ON
TRIGger<m>:CXPI:ERRor:IBS <ErrorIBS>
Triggers on an inter-byte-space (IBS) error, if TRIGger<m>:CXPI:TYPE is set to
ERRor.
Suffix:
<m>
.
1..3
Protocols