Protocol analysis
R&S
®
RTE
635User Manual 1326.1032.02 ─ 20
The setup conditions are the same as in the FlexRay trigger setup, see "Cycle count
(min, max), Step" on page 624.
Remote command:
SEARch:TRIGger:FLXRay:CENable on page 1578
SEARch:TRIGger:FLXRay:CMIN on page 1579
SEARch:TRIGger:FLXRay:CMAX on page 1579
SEARch:TRIGger:FLXRay:CSTep on page 1579
Position, Index (min, max) - Data setup
Sets the position of the first byte of data bit pattern within the payload segment. You
can define an exact position, or a position range.
The setup conditions are the same as in the FlexRay trigger setup, see "Position, Index
(min, max) - Data setup" on page 625.
Remote command:
SEARch:TRIGger:FLXRay:DPOPerator on page 1581
SEARch:TRIGger:FLXRay:DPOSition on page 1581
SEARch:TRIGger:FLXRay:DPTO on page 1581
Condition, Data (min, max) - Data setup
Specifies the data bit pattern to be found in the payload segment. The starting point of
the pattern is defined by "Position, Index (min, max) - Data setup" on page 635. The
pattern comparison is byte-aligned, and the instrument triggers at the end of a byte.
The setup conditions are the same as in the FlexRay trigger setup, see "Condition,
Data (min, max) - Data setup" on page 625.
Remote command:
SEARch:TRIGger:FLXRay:DCONdition on page 1580
SEARch:TRIGger:FLXRay:DMIN on page 1580
SEARch:TRIGger:FLXRay:DMAX on page 1580
Symbol
Searches for a symbol or a wakeup pattern.
"CAS/MTS"
Collision Avoidance Symbol / Media access Test Symbol. These sym-
bols are identical and can be sent in the optional symbol window at
the end of a communication cycle. They are used to avoid collisions
during the system start.
"Wakeup Pat-
tern"
The wakeup pattern is sent to activate the nodes of the system.
Remote command:
SEARch:TRIGger:FLXRay:SYMBol on page 1585
Error Condition
Selects the error type to be searched for. You can select one or more error types as
search condition.
The error types are the same as in the FlexRay trigger setup, see "Error conditions"
on page 626.