TC1796
Peripheral Units (Vol. 2 of 2)
Asynchronous/Synchronous Serial Interface (ASC)
User’s Manual 19-26 V2.0, 2007-07
ASC, V2.0
Note: When the set and clear bits for an error flag are set at the same time during a
WHBCON write operation (e.g SETPE = CLRPE = 1), the error flag in CON is not
affected.
SETPE 11 w Set Parity Error Flag
0
B
No effect.
1
B
Bit CON.PE is set.
Bit is always read as 0.
SETFE 12 w Set Framing Error Flag
0
B
No effect.
1
B
Bit CON.FE is set.
Bit is always read as 0.
SETOE 13 w Set Overrun Error Flag
0
B
No effect.
1
B
Bit CON.OE is set.
Bit is always read as 0.
0 [3:0],
[7:6],
[31:14]
r Reserved
Read as 0; should be written with 0.
Field Bits Type Description