EasyManua.ls Logo

Infineon Technologies TC1796 - Page 1394

Infineon Technologies TC1796
2150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual 22-99 V2.0, 2007-07
MultiCAN, V2.0
The Message Object Interrupt Pointer Register MOIPRn holds the message interrupt
pointers, the message pending number, and the frame counter value of message
object n.
MOIPRn (n = 0-127)
Message Object n Interrupt Pointer Register
(0608
H
+n*20
H
) Reset Value: 0000 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
CFCVAL
rwh
1514131211109876543210
MPN TXINP RXINP
rw rw rw
Field Bits Type Description
RXINP [3:0] rw Receive Interrupt Node Pointer
RXINP selects the interrupt output line INT_Om
(m = 0-15) for a receive interrupt event of message
object n. RXINP can also be taken for message
pending bit selection (see Page 22-42).
0000
B
Interrupt output line INT_O0 is selected.
0001
B
Interrupt output line INT_O1 is selected.
B
1110
B
Interrupt output line INT_O14 is selected.
1111
B
Interrupt output line INT_O15 is selected.
TXINP [7:4] rw Transmit Interrupt Node Pointer
TXINP selects the interrupt output line INT_Om
(m = 0-15) for a transmit interrupt event of message
object n. TXINP can also be taken for message
pending bit selection (see Page 22-42).
0000
B
Interrupt output line INT_O0 is selected.
0001
B
Interrupt output line INT_O1 is selected.
B
1110
B
Interrupt output line INT_O14 is selected.
1111
B
Interrupt output line INT_O15 is selected.

Table of Contents