TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual 22-100 V2.0, 2007-07
MultiCAN, V2.0
MPN [15:8] rw Message Pending Number
This bit field selects the bit position of the bit in the
Message Pending Register that is set upon a
message object n receive/transmit interrupt.
CFCVAL [31:16] rwh CAN Frame Counter Value
When a message is stored in message object n or
message object n has been successfully transmitted,
the CAN frame counter value NFCRx.CFC is then
copied to CFCVAL.
Field Bits Type Description