TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual 22-181 V2.0, 2007-07
MultiCAN, V2.0
STE 4wSoftware Trigger Event
This bit can be used to synchronize a TTCAN node
by software.
0
B
No action
1
B
The transmission of a reference message is
triggered if TTCR.ETESEL = 11 and the
system is in-a-gap.
ETREVR 5wReset External Trigger Event
This bit clears the external trigger event flag.
0
B
No action.
1
B
The bit TTSR.ETREV is cleared.
0 [31:6] r Reserved
Read as 0; should be written with 0.
Field Bits Type Description