TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual 23-96 V2.0, 2007-07
MLI, V2.0
AP [15:6] rh Address Prediction Factor
This bit field indicates the delta value (positive or
negative number) of offset address used by the MLI
transmitter for the next address prediction. AP is a
signed 9-bit number (10th bit is the sign bit) that is written
with each transmitter address prediction calculation (see
Page 23-24 and Page 23-45).
OP 16 rh Use Optimized Frame
When address optimization is enabled with
TCR.NO = 0, this bit indicates if address prediction is
possible in the transmitter. OP is written with each
transmitter address prediction calculation (see
Page 23-24 and Page 23-45).
0
B
No address prediction is possible. A Write Offset
and Data Frame or a Discrete Read Frame are
used for transmission.
1
B
Address prediction is possible. An Optimized
Write Frame or an Optimized Read Frame are
used for transmission.
0 [31:17] r Reserved
Read as 0; should be written with 0.
Field Bits Type Description