TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-22 V2.0, 2007-07
GPTA, V2.0
Figure 24-14 Compensation of Input Jitter
Positioning System with Three Sensors
The 3-sensor Mode is enabled when bit PDLCTR.TSEx is set to 1. The sensors are
mounted at an 120
°
angle to each other (see Figure 24-15). This configuration can
measure an absolute position with a resolution of 60°.
Input signal combinations that are not allowed in a properly-working positioning system
(all inputs low or all inputs high) cause the following to occur:
An error signal is generated, driving the Duty Cycle Measurement cells DCM1 and/or
DCM3,
The error flag PDLCTR.ERRx is set,
No forward or backward pulses are generated.
When the error disappears, the error signal will be cleared. The error flag
PDLCTR.ERRx must be cleared by software.
! Means not
Re Means rising edge
Fe Means falling edge
Forward ReS1*!S2*S3 + FeS3*S1*!S2 + ReS2*S1*!S3
+ FeS1*S2*!S3 + ReS3*!S1*S2 + FeS2*!S1*S3
Backward ReS1*S2*!S3 + FeS3*!S1*S2 + ReS2*!S1*S3
+ FeS1*!S2*S3 + ReS3*S1*!S2 + FeS2*S1*!S3
Error The input signal states S1*S2*S3 and !S1*!S2*!S3 are not allowed
Position Forward_Counter - Backward_Counter
MCT05923
S1
S2
Forward
Backward
Jitter Jitter