TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual 24-270 V2.0, 2007-07
GPTA, V2.0
The clock enable/disable control register controls two functions: clock enable/disable
control for each Global Timer in the GPTA0/GPTA1 modules and enable/disable control
for the module timer clocks, separately for each clock f
GPTA0
, f
GPTA1
, and f
LTCA2
.
GPTA0_EDCTR
GPTA Clock Enable/Disable Control Register
(400
H
) Reset Value: 0000 0000
H
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
0
r
1514131211109876543210
0
L2
EN
G1
EN
G0
EN
0
GT
11
RUN
GT
10
RUN
GT
01
RUN
GT
00
RUN
r rw rw rw r rw rw rw rw
Field Bits Type Description
GT00RUN 0rwGPTA0 Global Timer 0 Run Control
0
B
GPTA0 Global Timer 0 clock is stopped.
1
B
GPTA0 Global Timer 0 clock is started/running.
GT01RUN 1rwGPTA0 Global Timer 1 Run Control
0
B
GPTA0 Global Timer 1 clock is stopped.
1
B
GPTA0 Global Timer 1 clock is started/running.
GT10RUN 2rwGPTA1 Global Timer 0 Run Control
0
B
GPTA1 Global Timer 0 clock is stopped.
1
B
GPTA1 Global Timer 0 clock is started/running.
GT11RUN 3rwGPTA1 Global Timer 1 Run Control
0
B
GPTA1 Global Timer 1 clock is stopped.
1
B
GPTA1 Global Timer 1 clock is started/running.
G0EN 8rwGPTA0 Timer Clock Enable
0
B
GPTA0 timer clock f
GPTA0
is disabled.
1
B
GPTA0 timer clock f
GPTA0
is enabled.
G1EN 9rwGPTA1 Timer Clock Enable
0
B
GPTA1 timer clock f
GPTA1
is disabled.
1
B
GPTA1 timer clock f
GPTA1
is enabled.